The Effects of Different Mesh Generation Methods on Computational Fluid Dynamic Analysis and Power Loss Assessment in Total Cavopulmonary Connection
Author:
Liu Yutong1, Pekkan Kerem1, Jones S. Casey1, Yoganathan Ajit P.1
Affiliation:
1. Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA
Abstract
The flow field and energetic efficiency of total cavopulmonary connection (TCPC) models have been studied by both in vitro experiment and computational fluid dynamics (CFD). All the previous CFD studies have employed the structured mesh generation method to create the TCPC simulation model. In this study, a realistic TCPC model with complete anatomical features was numerically simulated using both structured and unstructured mesh generation methods. The flow fields and energy losses were compared in these two meshes. Two different energy loss calculation methods, the control volume and viscous dissipation methods, were investigated. The energy losses were also compared to the in vitro experimental results. The results demonstrated that: (1) the flow fields in the structured model were qualitatively similar to the unstructured model; (2) more vortices were present in the structured model than in the unstructured model; (3) both models had the least energy loss when flow was equally distributed to the left and right pulmonary arteries, while high losses occurred for extreme pulmonary arterial flow splits; (4) the energy loss results calculated using the same method were significantly different for different meshes; and (5) the energy loss results calculated using different methods were significantly different for the same mesh.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference21 articles.
1. de Leval, M. R., Kilner, P., Gewillig, M., and Bull, C., 1988, “Total Cavopulmonary Connection: A Logical Alternative to Atriopulmonary Connection for Complex Fontan Operations. Experimental Studies and Early Clinical Experience,” J. Thorac. Cardiovasc. Surg., 96, pp. 682–695. 2. Jonas, R. A., and Castaneda, A. R., 1988, “Modified Fontan Procedure: Atrial Baffle and Systemic to Pulmonary Artery Anastomosis Technique,” J. Card. Surg., 3, pp. 91–96. 3. Puga, F. I., Chiavarelli, M., and Hagler, D. J., 1987, “Modifications of the Fontan Operation Applicable to Patients With the Left Atrioventricular Valve Atresia or Single Atrioventricular Valve,” Circulation, 76, pp. III-53–III-60III-53–III-60. 4. de Leval, M. R. , 1998, “The Fontan Circulation: What Have We Learned? What to Expect?” Pediatr. Cardiol., 19, pp. 316–320. 5. Sharma, S., Goudy, S., Walker, P., Panchal, S., Ensley, A., Kanter, K., Tam, V., Fyfe, D., and Yoganathan, A., 1996, “In Vitro Flow Experiments for Determination of Optimal Geometry of Total Cavopulmonary Connection for Surgical Repair of Children With Functional Single Ventricle,” J. Am. Coll. Cardiol., 27, pp. 1264–1269.
Cited by
36 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|