Abstract

Film cooling designs are often evaluated experimentally and characterized in terms of their spatial distributions of adiabatic effectiveness, η, which is the nondimensionalized form of the adiabatic wall temperature, Taw. Additionally, film cooling may alter the convective heat transfer coefficient with the possibility of an increase in h that offsets the benefits of reduced Taw. It is therefore necessary to combine these two effects to give some measure of the benefit of film cooling. The most frequently used method is the net heat flux reduction (NHFR), which gives the fractional reduction in heat flux that accompanies film cooling for the hypothetical case of constant wall temperature. NHFR is imperfect in part due to the fact that this assumption does not account for the primary purpose of film cooling—to reduce the metal temperature to an acceptable level. In the present work, we present an alternative method of evaluating film cooling performance that yields the reduction in metal temperature, or in the nondimensional sense, an increase in ϕ that would be predicted with film cooling. This Δϕ approach is then applied using experimentally obtained η and h/h0 values on a simulated turbine blade leading edge region. The delta-phi approach agrees well with the legacy NHFR technique in terms of the binary question of whether the film cooling is beneficial or detrimental, but provides greater insight into the temperature reduction that a film cooling design would provide an actual turbine component. For example, instead of giving an area-averaged NHFR = 0.67 (indicating a 67% reduction in heat flux through film cooling) on the leading edge region with M = 0.5, the Δϕ approach indicates an increase in ϕ of 0.061 (or a 61 K surface temperature decrease with a notional value of T∞ −Tc = 1000 K). Alternatively, the technique may be applied to predict the maximum allowable increase in T∞ against which a film cooling scheme could protect.

Publisher

ASME International

Subject

Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3