Affiliation:
1. National Electric Coil, Columbus, OH
2. Maughan Generator Consultants, Schenectady, NY
Abstract
Stator windings that are in resonance will have high levels of vibration, if not properly damped or braced. Windings in resonance can suffer from early conductor strand fatigue cracking, arcing and failure during operation. Evidence of high vibration can sometimes be seen through visual inspection, with observance of dusting and greasing. There are two primary methods to anticipate and detect end winding resonant vibration — the bump test and on-line monitoring. Both are important and play a key role in identifying stator winding resonance problems, as well as implementing the appropriate solution. This paper will discuss the reasons that stator end winding resonance occurs. The technology, as well as the advantages and limitations of both the bump test and vibration monitoring, will be discussed. Solution approaches to end winding vibration are included, as well as one case history.
Publisher
American Society of Mechanical Engineers
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献