CFD Analysis of Ventilation Flow for a Scale Model Hydro-Generator

Author:

Toussaint Kristopher1,Torriano Federico1,Morissette Jean-Franc¸ois1,Hudon Claude1,Reggio Marcelo2

Affiliation:

1. IREQ – Hydro-Que´bec, Varennes, QC, Canada

2. E´cole Polytechnique de Montreal, Montreal, QC, Canada

Abstract

In 2006, the first Computational Fluid Dynamics (CFD) simulations of the ventilation of specific hydro-generator components were performed at the Hydro-Que´bec Research Institute (IREQ) and lately the entire ventilation circuit is being investigated. Due to the complexity of flow calculations, a validation process is necessary and for this reason a 1:4 scale model of a hydro-generator has been built at IREQ to get experimental data by means of particle image velocimetry (PIV). This paper presents 2D and 3D simulation results for the scale model obtained with a commercial CFD code and addresses the challenges associated with the application of CFD to hydro-generators. In particular, the effect of rotor-stator interface (RSI) types and configuration is analyzed to determine the approach that best suits this application. Two-dimensional calculations show that the steady state multiple frames of reference (MFR) solution is highly sensitive to the type (frozen rotor (FR) vs. mixing plane (MP)) and location of the RSI. A parametric study is performed where each interface configuration is compared to the transient case results. The MFR-FR interface model produces results that may vary significantly depending on the relative rotor position and the radial location of the RSI in the air gap. The MFR-MP interface model appears to be more coherent with reference values obtained from a transient case, since the radial velocity profiles in the stator are similar. Furthermore with an appropriate radial positioning of the interface, the windage losses are within 20%. Simulations of the complete 3D ventilation circuit revealed a maximum variation of 10% in both total ventilation flow rate and total windage losses, between the RSI configurations studied. However, the relative flow distributions, normalized with respect to the total flow rate, are unaffected by changes in RSI configuration. This paper focuses mainly on sensitivity studies to numerical settings, but this comparison still requires experimental validation before any final conclusions can be made.

Publisher

ASMEDC

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司