Affiliation:
1. St. Anthony Falls Hydraulic Laboratory, University of Minnesota, Minneapolis, MN 55414-2196
Abstract
Design studies are described for two recently completed large scale hydroacoustic test facilities (one of which is the world’s largest). These recirculating water tunnels have a different configuration than conventional tunnels, and special hydrodynamic design studies were required to evaluate and optimize the performance of some critical components. This paper considers the flow quality in the test section as influenced by the design of the contraction and the turbulence management system. Numerical modeling and experimental work were used to arrive at an acceptable nonsymmetrical nozzle design. Studies were also made of a turbulence management system using honeycombs rather than screens as typically used. Although design goals for turbulence levels were met, this study indicated that additional research in the area of turbulence management is necessary before there is a complete understanding of the overall process of turbulence attenuation.
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献