An Apparatus and Protocol to Measure Shoulder Girdle Strength

Author:

Garner Brian A.1,Shim Jaeho2,Wilson Scott1

Affiliation:

1. Department of Mechanical Engineering, Baylor University, One Bear Place 97356, Waco, Texas 76798

2. Department of Health, Human Performance, and Recreation, Baylor University, One Bear Place 97313, Waco, Texas 76798

Abstract

Muscles actuating the shoulder girdle are important for stabilizing the scapula and coordinating phased kinematics of the shoulder complex. If these muscles become weak or imbalanced, joint instability and injury may result. Reliable measurement of shoulder strength is thus important for prevention, diagnosis, and rehabilitation of shoulder problems. To date, studies quantifying the strength of the shoulder girdle are limited. The purpose of this work was to design and evaluate a custom apparatus and corresponding protocol for measuring maximal, voluntary, isometric strength of the shoulder girdle during various forms of shrugging exercise. A custom apparatus was constructed as a rigid frame with a vertical post supporting a seat, seat back, and horizontal beam. The beam extends laterally on either side beyond and around the shoulders of a seated subject. A pair of arm extension members pivots on the beam about an axis aligned with the shoulder flexion-extension axis. These members can be locked in place at any angle. Between them is mounted a force-sensing grip assembly, which can be adjusted proximally or distally to accommodate varying shoulder girdle positions. Subjects grasp the grip assembly handles with extended elbows and push or pull as forcefully as possible. Nine female and ten male subjects participated in a protocol using the apparatus to measure maximum isometric force generated at three positions each for elevation, depression, protraction, and retraction of the shoulder girdle (3positions×4modes=12tests). A video motion capture system was used to measure shoulder girdle angles. The reliability of the approach was evaluated based on the repeatability of measured shoulder elevation angle, protraction angle, and total force over three days of testing. The apparatus performed well during the tests, providing a stable, rigid, yet adjustable platform for measuring shoulder girdle strength. Repeatability of force measurements was interpreted as very good to excellent, with intraclass correlation coefficient (ICC) (2,1) values ranging from 0.83 to 0.95 for all tests except one (ICC=0.79). Repeatability of angle measurements was interpreted as good to excellent. For tests measuring elevation and depression strength, the ICC of elevation angle ranged from 0.85 to 0.89. For tests measuring protraction and retraction strength, the ICC of protraction angle ranged from 0.68 to 0.88. This type of apparatus could be an effective clinical tool for measuring strength in the shoulder girdle muscles. Use of the video motion capture system is optional.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3