In Vitro Pulsatility Analysis of Axial-Flow and Centrifugal-Flow Left Ventricular Assist Devices

Author:

Stanfield J. Ryan1,Selzman Craig H.2

Affiliation:

1. Department of Mechanical Engineering, University of Utah, 50 S Central Campus Dr., Rm. 2110, Salt Lake City, UT 84112 e-mail:

2. Department of Surgery, Division of Cardiothoracic Surgery, University of Utah, 30 N 1900 E, SOM 3C127, Salt Lake City, UT 84132

Abstract

Recently, continuous-flow ventricular assist devices (CF-VADs) have supplanted older, pulsatile-flow pumps, for treating patients with advanced heart failure. Despite the excellent results of the newer generation devices, the effects of long-term loss of pulsatility remain unknown. The aim of this study is to compare the ability of both axial and centrifugal continuous-flow pumps to intrinsically modify pulsatility when placed under physiologically diverse conditions. Four VADs, two axial- and two centrifugal-flow, were evaluated on a mock circulatory flow system. Each VAD was operated at a constant impeller speed over three hypothetical cardiac conditions: normo-tensive, hypertensive, and hypotensive. Pulsatility index (PI) was compared for each device under each condition. Centrifugal-flow devices had a higher PI than that of axial-flow pumps. Under normo-tension, flow PI was 0.98 ± 0.03 and 1.50 ± 0.02 for the axial and centrifugal groups, respectively (p < 0.01). Under hypertension, flow PI was 1.90 ± 0.16 and 4.21 ± 0.29 for the axial and centrifugal pumps, respectively (p = 0.01). Under hypotension, PI was 0.73 ± 0.02 and 0.78 ± 0.02 for the axial and centrifugal groups, respectively (p = 0.13). All tested CF-VADs were capable of maintaining some pulsatile-flow when connected in parallel with our mock ventricle. We conclude that centrifugal-flow devices outperform the axial pumps from the basis of PI under tested conditions.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference27 articles.

1. Perfusion of the Pulmonary Circulation by Nonpulsatile Flow;Surgery,1953

2. Is a Pulsatile Cardiac Prosthesis a Dying Dinosaur?;Artif. Organs,1992

3. Pulsatile versus Nonpulsatile Cardiopulmonary Bypass: No Difference in Brain Blood Flow or Metabolism at 27  °C,1994

4. Extended Mechanical Circulatory Support With a Continuous-Flow Rotary LVAD;J. Am. Coll. Cardiol.,2009

5. Advanced Heart Failure Treated With Continuous-Flow LVAD;New Engl. J. Med.,2009

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3