Affiliation:
1. Allison Gas Turbine Division, General Motors Corporation, Indianapolis, IN 46206
Abstract
Deposition, erosion, and corrosion (DEC) experiments were conducted using three coal-water fuels (CWF) in a staged subscale turbine combustor operated at conditions of a recuperated turbine. This rich-quench-lean (RQL) combustor appears promising for reducing NOx levels to acceptable levels for future turbines operating with CWF. Specimens were exposed in two test sections to the combustion products from the RQL combustor. The gas and most surface temperatures in the first and second test sections represented temperatures in the first stators and rotors, respectively, of a recuperated turbine. The test results indicate deposition is affected substantially by gas temperature, surface temperature, and unburned carbon due to incomplete combustion. The high rates of deposition observed at first stator conditions showed the need for additional tests to identify CWF coals with lower deposition tendencies and to explore deposition control measures such as hot gas cleanup.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
44 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献