The present article experimentally investigates the triggering and transient growth of azimuthal instabilities in a pressurized laboratory-scale annular combustor featuring 12 methane/hydrogen flames, as the equivalence ratio is ramped up and down. The ramping rate of equivalence ratio is varied to examine its effect on the transient thermo-acoustic response and the driving mechanisms, highlighting a number of previously unseen features. As the equivalence ratio is dynamically increased, all cases were observed to feature a distinct modal trajectory, during the onset of high-amplitude instabilities. Strongly spinning counterclockwise modes are first excited before a dynamic transition to strongly spinning clockwise modes occurs. Furthermore, the strength of the spinning mode (quantified through the spin ratio or nature angle) was shown to feature a local minima before the spinning mode stabilized in the system, which corresponds to an almost pure spinning state. Hysteresis behavior was observed in both the amplitude and nature of the mode, resulting in different thresholds for the onset and decay of the instability, depending on the time history of the combustor. Increasing the ramping rate was found to reduce the amount of hysteresis in the system. Furthermore, the high amplitude of the instability resulted in significant harmonic components. The behavior of the harmonics generally resembles the fundamental component, albeit with some notable exceptions.
Funder
European Research Council
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献