Experimental Investigation of Melt Coolability and Ablation Behavior of Oxidic Sacrificial Material at Prototypic Conditions in Scaled Down Core Catcher

Author:

Munot Samyak S.1,V Ganesh2,Kulkarni Parimal P.2,Nayak Arun K.3

Affiliation:

1. Engineering Sciences, Homi Bhabha National Institute, Anushakti Nagar, Mumbai, Maharashtra 400094, India e-mails: ;

2. Reactor Engineering Division, Bhabha Atomic Research Centre, Mumbai, Maharashtra 400085, India e-mail:

3. Reactor Engineering Division, Bhabha Atomic Research Centre, Mumbai, Maharashtra 400085, India; Engineering Sciences, Homi Bhabha National Institute, Anushakti Nagar, Mumbai, Maharashtra 400094, India e-mail:

Abstract

To minimize the potential risk of design extension conditions (DEC) with core meltdown, some advanced reactors employ ex-vessel core catchers which stabilize and cool the corium for prolonged period by strategically flooding it. This paper describes the coolability of the melt pool and ablation process in a scaled down ex-vessel core catcher employing sacrificial material which reduces the specific volumetric heat, temperature, and density of the melt pool. To understand these phenomena, a simulated experiment was carried out. The experiment was performed by melting about 500 kg of corium simulant using thermite reaction at about 2500 °C. The bricks of oxidic sacrificial material were arranged in the core catcher vessel which was surrounded by a tank filled with water up to a certain level. After the time required for melt inversion, water was introduced to flood the test section from the top. The melt pool temperatures were monitored at various locations using “K” and “C” type thermocouples to obtain ablation depth at different elevations with time. The results show that the coolability of the molten pool in the presence of water for the present geometry is achievable with outside vessel temperatures not exceeding 100 °C. A ceramic stable crust was observed at the top surface of the melt pool, which prevented water ingression into the molten corium. The ablation rate was found to be maximum at the lower corners of the brick arrangement with the maximum value being 0.75 mm/s. An average rate of about 0.18 mm/s was obtained in the brick matrix.

Publisher

ASME International

Subject

Nuclear Energy and Engineering,Radiation

Reference19 articles.

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3