Thermal Inactivation of Airborne SARS-CoV-2 by an Electric Fan Heater in Winter and Defining Conditions to Ensure That All the Air Passes Through the Fan

Author:

Canpolat Murat1,Şakalar Çağrı2,Bozkurt Serhat3,Çoban Ahmet Yılmaz4,Karaçaylı Deniz1,Toker Emre5

Affiliation:

1. Akdeniz University Biomedical Optics Research Unit, Department of Biophysics, Faculty of Medicine, , Antalya 07070 , Turkey

2. Antimikrop Ar-Ge ve Biyosidal Analiz Merkezi , Nasuh Akar Mah. Süleyman Hacıabdullahoğlu Cad. No: 37/1, Çankaya, Ankara 06520 , Turkey

3. Antalya Belek University Pharmancy Services Program, Vocational School, , Antalya 07525 , Turkey

4. Akdeniz University Tuberculosis Research Center; Department of Nutrition & Dietetics, Faculty of Health Sciences, , Antalya 07070 , Turkey

5. University of Arizona College of Agriculture & Life Sciences, , Saguaro Hall 129, 110 E. South Campus Dr. Tucson, AZ 87571-0033

Abstract

Abstract The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spread, especially in closed environments, by airborne transmission. The study aims to assess the thermal inactivation of airborne SARS-CoV-2 in a 30 m3 test room as a function of outlet temperature, airflow rate, and operating time of an electric heater, then define a condition to ensure that all air in the room passes through the electric heater. Aerosolized SARS-CoV-2 was delivered to the test room at an ambient temperature of 20 °C and 40% humidity. Two electric heaters with different powers and airflow rates were operated respectively in the test room to compare their efficiencies in the inactivation of airborne SARS-CoV-2. The first and second electric heaters had power, airflow rates, and outlet temperatures of 1.5 kW, 44 m3/h, 220 °C, and 3 kW, 324 m3/h, and 150 °C, respectively. A fan drew the outside air into the heater. In the first experiment, a 1.5 kW electric heater was operated in the test room for 80 min. In the second experiment, a 3 kW electric heater was used in the test room for 75 min. Airborne SARS-CoV-2 in the test room was inactivated by 99.00% and 99.96% in the first and second experiments, respectively. A condition is defined to ensure that all the air in the room passes at least once through the electric heater fan.

Publisher

ASME International

Subject

Fluid Flow and Transfer Processes,General Engineering,Condensed Matter Physics,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3