Abstract

Musculoskeletal modeling and simulation techniques have been used to gain insights into movement disabilities for many populations, such as ambulatory children with cerebral palsy (CP). The individuals who can benefit from these techniques are often limited to those who can walk without assistive devices, due to challenges in accurately modeling these devices. Specifically, many children with CP require the use of ankle-foot orthoses (AFOs) to improve their walking ability, and modeling these devices is important to understand their role in walking mechanics. The purpose of this study was to quantify the effects of AFO mechanical property assumptions, including rotational stiffness, damping, and equilibrium angle of the ankle and subtalar joints, on the estimation of lower-limb muscle forces during stance for children with CP. We analyzed two walking gait cycles for two children with CP while they were wearing their own prescribed AFOs. We generated 1000-trial Monte Carlo simulations for each of the walking gait cycles, resulting in a total of 4000 walking simulations. We found that AFO mechanical property assumptions influenced the force estimates for all the muscles in the model, with the ankle muscles having the largest resulting variability. Muscle forces were most sensitive to assumptions of AFO ankle and subtalar stiffness, which should therefore be measured when possible. Muscle force estimates were less sensitive to estimates of damping and equilibrium angle. When stiffness measurements are not available, limitations on the accuracy of muscle force estimates for all the muscles in the model, especially the ankle muscles, should be acknowledged.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3