Affiliation:
1. Bechtel Infrastructure & Power Corp. , Reston, VA 20170
2. Bechtel Ltd. , London NW10 7FQ, UK
Abstract
Abstract
Modern heavy duty industrial gas turbines in combined cycle configuration, with rated efficiencies (at ISO base load) above 60% net LHV, are expected to play a significant role in reducing the carbon footprint of utility scale electricity generation. Even without postcombustion capture (PCC), simply switching from coal-fired generation to natural gas-fired generation reduces carbon dioxide emissions by 60% (on a kg per MWh of generation basis). In simple cycle mode, with efficiencies above 40% net LHV and startup times around 20 min, 300–400+ MW gas turbines can easily serve as peakers to support variable renewable resources, i.e., wind and solar. In this paper, a close quantitative look is taken at the capabilities of gas turbines firing natural gas, hydrogen, or a blend thereof, both in simple and combined cycle configurations. Furthermore, using published data, first-principles calculations, and software simulations, it will be shown that the gas turbine constitutes an efficient and cost-effective technology, with and without carbon capture, as a key player in decarbonization of the electric power sector.
Reference36 articles.
1. The Logistics and Economics of a CO2 Flood,1983
2. Leading Options for the Capture of CO2 Emissions at Power Stations;IEA GHG,2000
3. MHI's Energy Efficient Flue Gas CO2 Capture Technology and Large-Scale CCS Demonstration Test at Coal-Fired Power Plants in USA;MHI Tech. Rev.,2011
4. Comparison of Different Amine Solvents for the Absorption of CO2;Chem. Eng. Trans.,2017