Affiliation:
1. Jet Propulsion Laboratory, California Institute of Technology, Pasadena, Calif.
Abstract
Boundary layer and heat transfer measurements are presented for flow through a cooled, conical nozzle with a convergent and divergent half-angle of 10 deg for a wall-to-total-gas temperature ratio of about 0.5. A reduction in heat transfer below values typical of a turbulent boundary layer was found when values of the parameter K = (μe/ρeue2) (due/dx) exceeded about 2 to 3 × 10−6. The boundary layer measurements, when viewed in conjunction with the heat transfer measurements, reveal the complicated nature of the flow and thermal behavior and their interrelationship when laminarization occurs.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
49 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献