This paper investigates experimentally and assesses the errors that may be incurred in the hue-based thermochromic liquid crystal (TLC) method, and their causes. The errors include response time, hysteresis, aging, surrounding illumination disturbance, direct illumination and viewing angle, illumination light intensity, TLC thickness, digital resolution of the image conversion system, and measurement noise. Some of the main conclusions are that (1) the 3×8 bits digital representation of the red, green and blue TLC color values produces a temperature measurement error of typically 1% of the TLC effective temperature range, (2) an 8-fold variation of the light intensity into the camera produced variations, which were not discernable from the digital resolution error, (3) this temperature depends on the TLC film thickness, (4) thicker films are less susceptible to aging and thickness nonuniformities.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Heat transfer from a cylinder in axial turbulent flows;International Journal of Heat and Mass Transfer;2005-04