Affiliation:
1. John Zink Company, LLC, Tulsa, OK
Abstract
A double fired process heater with combination oil/gas burners has been modeled with computational fluid dynamics (CFD). The process heater was simulated with two configurations: 1) with internal walls, and 2) without internal walls. The purpose of this study is to understand the effect of the internal walls on flame shape and process tube heat flux. As a result of removing the internal wall, furnace currents are allowed to have a large influence on the flame patterns and the flames lean toward the tubes. It is also shown that higher localized heat fluxes occur on the process tubes with the walls removed. This study demonstrates that the primary function of the internal walls is to isolate cells within the furnace which create satisfactory process tube heat fluxes.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献