Day-to-Day Reliability of Nonlinear Methods to Assess Walking Dynamics

Author:

Raffalt P. C.12,Alkjær T.3,Brynjólfsson B.3,Jørgensen L.3,Bartholdy C.45,Henriksen M.45

Affiliation:

1. Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charité—Universitätsmedizin Berlin, Augustenburger Platz 1, Berlin 13353, Germany;

2. Department of Biomedical Sciences, University of Copenhagen, Copenhagen 2200, Denmark e-mail:

3. Department of Biomedical Sciences, University of Copenhagen, Copenhagen 2200, Denmark

4. The Parker Institute, Copenhagen University Hospital Bispebjerg, Frederiksberg 2000, Denmark;

5. Department of Physical and Occupational Therapy, Copenhagen University Hospital Bispebjerg, Frederiksberg 2000, Denmark

Abstract

The present study investigated the day-to-day reliability (quantified by the absolute and relative reliability) of nonlinear methods used to assess human locomotion dynamics. Twenty-four participants of whom twelve were diagnosed with knee osteoarthritis completed 5 min of treadmill walking at self-selected preferred speed on two separate days. Lower limb kinematics were recorded at 100 Hz and hip, knee, and ankle joint angles, three-dimensional (3D) sacrum marker displacement and stride time intervals were extracted for 170 consecutive strides. The largest Lyapunov exponent and correlation dimension were calculated for the joint angle and sacrum displacement data using three different state space reconstruction methods (group average, test-retest average, individual time delay and embedding dimension). Sample entropy and detrended fluctuation analysis (DFA) were applied to the stride time interval time series. Relative reliability was assessed using intraclass correlation coefficients and absolute reliability was determined using measurement error (ME). For both joint angles and sacrum displacement, there was a general pattern that the group average state space reconstruction method provided the highest relative reliability and lowest ME compared to the individual and test-retest average methods. The DFA exhibited good reliability, while the sample entropy showed poor reliability. The results comprise a reference material that can inspire and guide future studies of nonlinear gait dynamics.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3