Affiliation:
1. Exxon Research & Engineering Co., Baytown, Texas
2. University of Houston, Houston, Texas
Abstract
Regression analysis is used to develop equations for calculating fusion temperatures of coal ash from chemical composition, based on 1250 analyses of ash from both eastern and western coal. Standard errors for the equations are generally less than 50°F (27°C), which is the analytical tolerance of the ash fusion temperature measurements. Equations are given for eastern, western, and combined eastern and western coals. These equations: (1) provide a technique for calculating ash fusion temperatures from the chemical composition of the ash; (2) provide a method for calculating the ash fusion properties of coal blends; and (3) provide an improved understanding of the effect, significance, and interactions of ash elements with respect to the thermal properties of coal ash.
Cited by
57 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献