Experimentally Measured Effects of Incidence Angle on the Adiabatic and Overall Effectiveness of a Fully Cooled Turbine Airfoil With Shaped Showerhead Holes

Author:

Chavez Kyle1,Slavens Thomas N.2,Bogard David1

Affiliation:

1. Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712 e-mail:

2. Pratt & Whitney, East Hartford, CT 06118 e-mail:

Abstract

Manufacturing and assembly variation can lead to shifts in the inlet flow incidence angles of a rotating turbine airfoil row. Understanding the sensitivity of the adiabatic film cooling effectiveness to a range of inlet conditions is necessary to verify the robustness of a cooling design. In order to investigate the effects of inlet flow incidence angles, adiabatic and overall effectiveness data were measured in a low speed linear cascade at 0 deg and 10 deg of the designed operating condition. Tests were completed at an inlet Reynolds number of Re = 120,000 and a turbulence intensity of Tu = 5% at the leading edge of the test article. Particle image velocimetry was used to verify the incident flow angle for each angle studied. The test section was first adjusted so that the pressure distribution and stagnation line of the airfoil matched those predicted by an aerodynamic computational fluid dynamics (CFD) model. IR thermography was then used to measure the adiabatic effectiveness levels of the fully cooled airfoil model with nine rows of shaped holes of varying construction and feed delivery. Measurements were taken over a range of blowing ratios and at a density ratio of DR = 1.23. This process was repeated for the two incidence angles measured, while the inlet pressure to the airfoil model was held constant for these incidence angle changes. Differences in laterally adiabatic effectiveness across the airfoil model were most evident in the showerhead, with changes as large as 0.2. The effect persisted most strongly at s/D = ±35 downstream of the stagnation row of holes, but was visible over the whole viewable area of 160 s/D. The effect was due to the stagnation line affecting the film at the showerhead row. Due to this effect, the showerhead was investigated in detail, including the effects of the stagnation line shift as well as the influence of the incidence angle on the overall effectiveness of the showerhead region. It was found that the stagnation line has the tendency to dramatically increase the near-hole adiabatic effectiveness levels when positioned within the breakout footprint of the hole. The effect persisted for the overall effectiveness study, since the hole spacing for this particular configuration was wide enough that the through hole convection was not completely dominant. This is the first study to present measured effectiveness values over both the pressure- and suction-side surfaces of a fully cooled airfoil for appreciably off-nominal incidence angles as well as examine adiabatic and overall effectiveness levels for a conical stagnation row of holes.

Funder

Office of Naval Research

Publisher

ASME International

Subject

Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3