Experimental Study on Performance of a Solar Thermal-Driven Vapor Absorption System Integrated With Hot Thermal Energy Storage for Milk Chilling

Author:

Sharma Dinesh Kumar12,Sharma Dilip2,Ali Ahmed Hamza H.3

Affiliation:

1. Swami Keshvanand Institute of Technology, Management and Gramothan Department of Mechanical Engineering, , Jaipur 302017 , India ;

2. Malaviya National Institute of Technology Department of Mechanical Engineering, , Jaipur 302017 , India

3. Assiut University Department of Mechanical Power Engineering, Faculty of Engineering, , Assiut 71516 , Egypt

Abstract

Abstract Solar thermal-driven vapor absorption system has proven to be a feasible and viable cooling source. However, most reported installations for milk chilling applications are equipped with an auxiliary heater that consumes significant electricity/gas, making it economically unviable. In this study, the experimental investigation of the performance of a solar-powered vapor absorption chiller has been reported for milk chilling applications as per standard ISO 5708–2 II. It has been identified that the performance of the vapor absorption chiller is quite uncertain and underperforming while operated with the heat directly fed through the evacuated tube compound parabolic concentrator solar field due to diurnal and seasonal variations of solar radiation intensity. Therefore, hot thermal energy storage integration has been studied and analyzed in this study. The performance of the vapor absorption chiller has improved significantly with the use of hot thermal energy storage in the solar circuit as the coefficient of performance (COP) of the vapor absorption chiller improved up to 0.4, which was earlier around 0.25. Further, hot thermal energy storage provides better thermal management to increase the productivity and performance of the vapor absorption chiller, and the cooling time for the first milking is 2 h and 45 min. The performance of the vapor absorption chiller enhanced further up to 0.52 when supplied heat entirely with thermal energy storage. The energy efficiency ratio has a maximum value of 6.1, with an average of 4.3, whereas the thermal COP has an average of 0.35 and a maximum value of 0.52 when run with thermal energy storage alone.

Publisher

ASME International

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3