Thermodynamic Performance Evaluation of a Solar Parabolic Dish Assisted Multigeneration System

Author:

Abid Muhammad1,Khan Muhammad Sajid2,Hussain Ratlamwala Tahir Abdul3

Affiliation:

1. Faculty of Engineering, Department of Energy Systems Engineering, Cyprus International University, North Cyprus via Mersin 10, Nicosia 10000, Turkey e-mail:

2. Department of Mechanical Engineering, Mirpur University of Science & Technology (MUST), Mirpur, 10250 AJK, Pakistan e-mail:

3. Department of Mechanical Engineering, National University of Sciences and Technology, Islamabad 24090, Pakistan e-mail:

Abstract

The concentration ratio of the parabolic dish solar collector (PDSC) is considered to be one of the highest among the concentrated solar power technologies (CSPs); therefore, such system is capable of generating more heat rate. The present paper focuses on the integration of the PDSC with the combined cycle (gas cycle as the toping cycle and steam cycle as the bottoming cycle) along with the utilization of waste heat from the power cycle to drive the single effect lithium bromide/water absorption cycle. Molten salt is used as a heat transfer fluid in the solar collector. The engineering equation solver (EES) is employed for the mathematical modeling and simulation of the solar integrated system. The various operating parameters (beam radiation, inlet and ambient temperatures of heat transfer fluid, mass flow rate of heat transfer fluid, evaporator temperature, and generator temperature) are varied to analyze their influence on the performance parameters (power output, overall energetic and exergetic efficiencies, outlet temperature of the receiver, and as coefficient of performance (COP) and exergy efficiencies) of the integrated system. The results show that the overall energy and exergy efficiencies are observed to be 39.9% and 42.95% at ambient temperature of 27 °C and solar irradiance of 1000 W/m2. The outlet temperature of the receiver is noticed to decrease from 1008 K to 528 K for an increase in the mass flow rate from 0.01 to 0.05 kg/s. The efficiency rate of the power plant is 38%, whereas COP of single effect absorption system is 0.84, and it will decrease from 0.87 to 0.79. However, the evaporator load is decreased to approximately 9.7% by increasing the generator temperature from 47 °C to 107 °C.

Publisher

ASME International

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3