Affiliation:
1. State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, People’s Republic of China
Abstract
Abstract
A nonintrusive measurement technique is presented numerically for simultaneous measurement of three-dimensional (3D) soot temperature and volume fraction fields in the axisymmetric or asymmetric flames with charge-coupled device (CCD) cameras. CCD cameras were introduced to capture the flame images for obtaining the line-of-sight radiation intensities. The distributions of local emission source under two wavelengths can be deduced through solving the reconstruction matrix equation by the least-square QR decomposition method from the knowledge of the line-of-sight radiation intensities of the flames. The two-color distributions of the local emission source were used to retrieve the soot temperature and volume fraction distributions. The effects of the discrete ray number of CCD cameras, the number of CCD cameras, and the system signal-to-noise ratio (SNR) on the measurement were investigated. The results show that for accurate measurement of soot volume fraction field, the CCD cameras number should not be less than four and the system SNR can be as low as 54 dB. The proposed technique can be capable for reconstructing the 3D soot temperature and volume fraction fields in both axisymmetric and asymmetric flames well.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
60 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献