Theoretical Investigation of Low Global Warming Potential Blends Replacing R404A: The Simple Refrigeration Cycle and Its Modifications

Author:

Belman-Flores J. M.1,Román-Aguilar R.2,Valle-Hernández J.2,Serrano-Arellano J.3

Affiliation:

1. University of Guanajuato IRSE Research Group, Department of Mechanical Engineering, Engineering Division, Campus Irapuato-Salamanca, , Salamanca-Valle de Santiago km 3.5+1.8, Salamanca, Guanajuato C.P. 36885 , Mexico

2. Universidad Autónoma del Estado de Hidalgo Departamento en Tecnología del Frío, Escuela Superior de Apan, , Colonia Chimalpa Tlalayote, Apan, Hidalgo C.P. 43900 , Mexico

3. Tecnológico Nacional de México/IT de Pachuca División de Estudios de Posgrado e Investigación, , Carretera México-Pachuca km. 87.5, Colonia Venta Prieta, Pachuca de Soto, Hidalgo C.P. 42080 , Mexico

Abstract

Abstract R404A refrigerant is one of the most widely used hydrofluorocarbons in the commercial refrigeration industry for low and medium temperatures. However, this refrigerant contributes negatively to the environment due to its high global warming potential (GWP = 3943), and for several years, it has been labeled as one of the refrigerants that should be phased out. The present study theoretically evaluates low-GWP refrigerants as a replacement alternative to R404A, including R407H, R442A, R449A, R454A, R454C, R455A, R459B, and R465A. The analysis focuses on the comparison between relative differences in the volumetric flow in the compressor suction and the coefficient of performance for four configurations of the vapor compression cycle, such as the basic cycle, the cycle with an internal heat exchanger, the cycle with direct injection, and the cycle with a sub-cooler. According to the proposed operating conditions of evaporation temperature (−10 °C and −40 °C) and condensation temperature (40 °C and 55 °C), R454A could be the best long-term replacement option for its low GWP, energy performance, and direct fit for any configuration. R459B could also be considered a viable option, but with certain design modifications. On the contrary, the refrigerants R465A, R455A, and R454C would be discarded because they present a greater non-adaptation to the compressor in each configuration analyzed.

Publisher

ASME International

Reference23 articles.

1. Regulation of the European Parliament and the Council of 16 April 2014 on Fluorinated Greenhouse Gases and Repealing Regulation (EC) N◦ 842/2006;Regulation (EU) No 517/2014,2014

2. Review of F-Gas Regulation-IIR Contribution;IIFIIR,2020

3. Montreal Protocol at 30: The Governance Structure, the Evolution, and the Kigali Amendment;Birmpili;C. R. Geosci.,2018

4. Analysis of Lower GWP and Flammable Alternative Refrigerants;Yang;Int. J. Refrig.,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3