Abstract

The large-scale production of renewable energy is limited by the intermittence nature of the renewable energy sources. Moreover, the electricity production of the thermal and nuclear power plants is not flexible with the electricity demand. Hence, the integration of energy storage technologies into the grid has become crucial as it creates a balance between supply and demand for electricity and protects thereby the electrical grid. Among the large-scale energy storage technologies, a novel adiabatic compressed air energy storage (A-CAES) system will be developed in this paper. This storage system is characterized, compared to the conventional compressed air energy storage (CAES) system, by the recovery and the reuse of the compression heat in order to improve the system efficiency and avoid the use of fossil fuel sources. This paper discusses a comparison between the static and dynamic modeling of the A-CAES system performed by a computer simulation using “Modelica.” Unlike the static model, the dynamic model takes into account the mechanical inertia of the turbomachinery (compressors and turbines) as well as the thermal inertia of the heat exchangers. Consequently, it enables studying the flexibility of the storage system and its ability to meet the electrical grid requirements (primary and secondary reserves) by evaluating the duration of the transient states. Furthermore, the comparison between the static and dynamic models permits to estimate the efficiency losses due to the transient evolutions.The results show that the storage system needs more than 2 min before being able to consume all the excess energy available on the electrical grid and more than 5 min before being able to produce all the energy required by the electrical grid. These time frames are due especially to the transient states (start-up) of the turbomachines. Finally, the system efficiency is 64.7%, the transient states of the system cause losses of 0.9%. These small losses are explained by the short duration of the transient states relative to that of the steady states (15 hrs).

Publisher

ASME International

Subject

Geochemistry and Petrology,Mechanical Engineering,Energy Engineering and Power Technology,Fuel Technology,Renewable Energy, Sustainability and the Environment

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3