Analysis of Compressor On-Line Washing to Optimize Gas Turbine Power Plant Performance

Author:

Schneider Ernst1,Demircioglu Saba1,Franco Susana1,Therkorn Dirk1

Affiliation:

1. ALSTOM (Switzerland) Ltd., Baden, Switzerland

Abstract

Due to compressor fouling, gas turbine efficiency decreases over time, resulting in decreased power output of the plant. To counteract the effects of compressor fouling, compressor on-line and off-line washing procedures are used. The effectiveness of compressor off-line washing is enhanced if combined with the cleaning of the VIGVs and the first compressor blade row by hand. This paper presents a thorough analysis of the effects of compressor on-line washing on the gas turbine performance. The analysis is based on the measured data of six gas turbines operated at two different plants. Different washing schedules and washing fluids are analyzed and compared. Furthermore, the effects of compressor on-line washing on the load distribution within the compressor are analyzed. The performance benefit of daily compressor on-line washing compared to weekly compressor on-line washing is quantified. As expected, daily compressor on-line washing yields the lowest power degradation caused by compressor fouling. Also, the effect of washing additives is analyzed. It is shown with long term data that compressor on-line washing cleans up to the first 11 compressor stages, as can be detected well in the compressor. With a view to gas turbine performance optimization, the recommendation is to perform compressor off-line washing at regular intervals and to take advantage of occasions such as inspections, when the gas turbine is cooled down anyhow. Especially for gas turbines with a high fouling rate, a daily compressor on-line washing schedule should be considered to reduce the power loss. For gas turbines operating with high fogging, compressor on-line washing has no added benefit. To determine the optimal compressor washing schedule, compressor blade erosion also has to be considered. A reasonable balance between compressor on-line washing and off-line washing improves the gas turbine performance and optimizes the gas turbine availability.

Publisher

ASMEDC

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3