Abstract

The normal knee joint maintains stable motion during activities of daily living. After total knee arthroplasty (TKA), stability is achieved by the conformity of the bearing surfaces of the implant components, ligaments, and constraint structures incorporated in the implant design. The large, rectangular tibial post in constrained condylar knee (CCK) arthroplasty, often used in revision surgery, provides added stability, but increases susceptibility to polyethylene wear as it contacts the intercondylar box on the femoral component. We examined coronal plane stability to understand the relative contributions of the mechanisms that act to stabilize the CCK knee under varus–valgus loading, namely, load distribution between the medial and lateral condyles, contact of the tibial post with the femoral intercondylar box, and elongation of the collateral ligaments. A robot testing system was used to determine the joint stability in human cadaveric knees as described by the moment versus angular rotation behavior under varus–valgus moments at 0 deg, 30 deg, and 90 deg of flexion. The angular rotation of the CCK knee in response to the physiological moments was limited to ≤1.5 deg. The primary stabilizing mechanism was the redistribution of the contact force on the bearing surfaces. Contact between the tibial post and the femoral box provided a secondary stabilizing mechanism after lift-off of a condyle had occurred. Collateral ligaments provide limited stability because little ligament elongation occurred under such small angular rotations. Compressive loads applied across the knee joint, such as would occur with the application of muscle forces, enhanced the ability of the bearing surfaces to provide resisting internal varus–valgus moment and, thus, reduced the exposure of the tibial post to the external varus–valgus loads. Our results suggest that the CCK stability can be refined by considering both the geometry of the bearing surfaces and the contacting geometry between the tibial post and femoral box.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference26 articles.

1. The Posterior Stabilized Condylar Prosthesis: A Modification of the Total Condylar Design: Two to Four-Year Clinical Experience;J. Bone Jt. Surg.,1982

2. Total Condylar III Knee Prosthesis. Long-Term Follow-Up Study;Clin. Orthop. Relat. Res.,1988

3. Ten-Year Survival and Clinical Results of Constrained Components in Primary Total Knee Arthroplasty;J. Arthroplasty,2006

4. Constrained Condylar Knee Without Stem Extensions for Difficult Primary Total Knee Arthroplasty;J. Knee Surg.,2007