Numerical Characterization of Diffusion-Based Extraction in Cell-Laden Flow Through a Microfluidic Channel

Author:

Fleming K. K.1,Longmire E. K.2,Hubel A.1

Affiliation:

1. Department of Mechanical Engineering, University of Minnesota, 1100 Mechanical Engineering, 111 Church Street, Minneapolis, Minnesota 55455

2. Department of Aerospace Engineering and Mechanics, University of Minnesota, 107 Akerman Hall, 110 Union Street SE, Minneapolis, Minnesota 55455

Abstract

Cells are routinely cryopreserved in dimethyl sulfoxide (DMSO), a cryoprotective agent, for medical applications. Infusion of a DMSO-laden cell suspension results in adverse patient reactions, but current DMSO extraction processes result in significant cell losses. A diffusion-based numerical model was employed to characterize DMSO extraction in fully developed channel flow containing a wash stream flowing parallel to a DMSO-laden cell suspension. DMSO was allowed to diffuse across cell membranes as well as across the channel depth. A variety of cases were considered with the ultimate goal of characterizing the optimal geometry and flow conditions to process clinical volumes of cell suspension in a reasonable time (2–3ml∕min). The results were dependent on four dimensionless parameters: depth fraction of the DMSO-laden stream, Peclet number, cell volume fraction in the DMSO-laden stream, and cell membrane permeability parameter. Smaller depth fractions led to faster DMSO extraction but channel widths that were not practical. Higher Peclet numbers led to longer channels but smaller widths. For the Peclet values and channel depths considered (⩾500μm) and appropriate permeability values, diffusion across cell membranes was significantly faster than diffusion across the channel depth. Cell volume fraction influenced the cross-stream diffusion of DMSO by limiting the fluid volume fraction available in the contaminant stream but did not play a significant role in channel geometry or operating requirements. The model was validated against preliminary experiments in which DMSO was extracted from suspensions of B-lymphoblast cells. The model results suggest that a channel device with practical dimensions can remove a sufficient level of contaminant within a mesoscale volume of cells in the required time.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3