Nonlinear Behavior of Trabecular Bone at Small Strains
Author:
Morgan Elise F.1, Yeh Oscar C.1, Chang Wesley C.1, Keaveny Tony M.23
Affiliation:
1. Orthopædic Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, CA 94720 2. Orthopædic Biomechanics Laboratory, Department of Mechanical Engineering, Department of Bioengineering, University of California, Berkeley, CA 94720 3. Department of Orthopædic Surgery, University of California, San Francisco, CA 94143
Abstract
Study of the behavior of trabecular bone at strains below 0.40 percent is of clinical and biomechanical importance. The goal of this work was to characterize, with respect to anatomic site, loading mode, and apparent density, the subtle concave downward stress–strain nonlinearity that has been observed recently for trabecular bone at these strains. Using protocols designed to minimize end-artifacts, 155 cylindrical cores from human vertebrae, proximal tibiae, proximal femora, and bovine proximal tibiae were mechanically tested to yield at 0.50 percent strain per second in tension or compression. The nonlinearity was quantified by the reduction in tangent modulus at 0.20 percent and 0.40 percent strain as compared to the initial modulus. For the pooled data, the mean±SD percentage reduction in tangent modulus at 0.20 percent strain was 9.07±3.24 percent in compression and 13.8±4.79 percent in tension. At 0.40 percent strain, these values were 23.5±5.71 and 35.7±7.10 percent, respectively. The magnitude of the nonlinearity depended on both anatomic site p<0.001 and loading mode p<0.001, and in tension was positively correlated with density. Calculated values of elastic modulus and yield properties depended on the strain range chosen to define modulus via a linear curve fit p<0.005. Mean percent differences in 0.20 percent offset yield strains were as large as 10.65 percent for some human sites. These results establish that trabecular bone exhibits nonlinearity at low strains, and that this behavior can confound intersite comparisons of mechanical properties. A nonlinear characterization of the small strain behavior of trabecular bone was introduced to characterize the initial stress–strain behavior more thoroughly.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference43 articles.
1. Jones, R. M., 1998, Mechanics of Composite Materials, 2nd ed., Taylor and Francis, Philadelphia. 2. Abufarsakh, G.
, 1989, “New Material Models for Nonlinear Stress Strain Behavior of Composite Materials,” Composites, 20, No. 4, pp. 349–360. 3. Jones, R. M., and Morgan, H. S., 1977, “Analysis of Nonlinear Stress–Strain Behavior of Fiber-Reinforced Composite Materials,” AIAA J., 15, No. 12, pp. 1669–1676. 4. Keaveny, T. M., Wachtel, E. F., Ford, C. M., and Hayes, W. C., 1994, “Differences Between the Tensile and Compressive Strengths of Bovine Tibial Trabecular Bone Depend on Modulus,” J. Biomech., 27, No. 9, pp. 1137–1146. 5. Kopperdahl, D. L., and Keaveny, T. M., 1998, “Yield Strain Behavior of Trabecular Bone,” J. Biomech., 31, No. 7, pp. 601–608.
Cited by
82 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|