Inspection of the Steam Generator Heat Transfer Tubes for FBR Monju Restart

Author:

Takahashi Kenji1,Shiina Akira1,Onizawa Takahiro1,Ibaki Shoji1,Yamaguchi Toshihiko1,Tagawa Akihiro1

Affiliation:

1. Japan Atomic Energy Agency, Tsuruga, Fukui, Japan

Abstract

Japanese prototype FBR Monju will restart its operation for the first time since the occurrence of the sodium leak accident in 1995. The integrity of its components after the long suspension needs to be confirmed before restarting. One of the most important components of Monju is steam generator (SG) unit that was first tested in the 2007.11–2008.3 period during plant-confirmation test. The safety authority required that Monju components should have as same integrity as at the beginning of the first operation in 1994. Now the SG tubes have been installed in the vessel and it is impossible to test them directly. In order to satisfy the safety authority requirement, presumable deteriorations of SG tubes in the long-term suspension were investigated at first and these were limited to only the lack of thickness by corrosion, which are detectable by three tests: eddy current testing (ECT), visual testing (VT), and leak check. These tests were performed with customized procedures and evaluated for appropriate criteria. The ECT was applied to check for the lack of thickness of SG tubes caused by regional corrosions. The ECT probe passes through the full length of a tube with the speed of 200mm/s. Integrity of the tube was checked by amplitude and phase chart. Threshold of the approval thickness was decided based on the tube data at the time of manufacturing. The thickness of the tube is 3.5mm and it cannot be reduced less than 7% lack of the thickness. The characteristic signal at special points like bends or SG support plates were identified by their phase chart. Based on these evaluations, no significant deterioration was detected in SG tubes excepting the special undetectable region. The VT checked for corrosions on the inner surface of tubes. It covers the undetectable regions by ECT. The testing region is between the tube-plate and the bottom U tube along the down comer. The condition of the other regions, subjected to the same environment conditions (temperature, humidity, time not being in service, others) is expected to be similar to the tested region. A customized CCD camera was operated with about 10 mm/s along the tube. The test did not reveal any significant corrosion. The leak test checked for penetrating holes in SG tubes. After keeping a high pressure argon gas outside of SG tube, the nitrogen gas inside of SG was pumped to a mass spectrometer. In this test, no argon gas was detected by the mass spectrometer. After evaluation of all results of three tests, it was confirmed that there is no significant lack of thickness and penetrating holes in SG tubes. Therefore, it was proved that SG heat transfer tubes have the required integrity for reoperation.

Publisher

ASMEDC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3