Fluid Dynamics of a Pre-Swirl Rotor-Stator System
Author:
Yan Youyou1, Gord Mahmood Farzaneh2, Lock Gary D.2, Wilson Michael2, Owen J. Michael2
Affiliation:
1. Aero, Civil and Mechanical Engineering, City University, London, Northampton Square, London EC1V 0HB, UK 2. Department of Mechanical Engineering, University of Bath, Bath BA2 7AY, UK
Abstract
In a “direct-transfer” pre-swirl supply system, cooling air flows axially across the wheel-space from stationary pre-swirl nozzles to receiver holes located at a similar radius in the rotating turbine disc. This paper describes a combined computational and experimental study of the fluid dynamics of such a system. Measurements of total and static pressures have been made using a purpose-built rotor-stator rig, with 24 pre-swirl nozzles on the stator and 60 receiver holes in the rotor. The number of pre-swirl nozzles could be reduced, and it was possible to calculate CD, the discharge coefficient of the receiver holes. Information on the flowfield was also obtained from three-dimensional, incompressible steady turbulent flow computations. The measurements showed that there was a significant loss of total pressure between the outlet from the pre-swirl nozzles and the rotating core of fluid in the wheel-space. This loss increased as the pre-swirl flow-rate and inlet swirl ratio increased, and as the number of nozzles decreased. CD increased as the swirl ratio at the receiver hole radius approached unity; also CD decreased as the number of nozzles decreased. Computed pressures and tangential velocities were in mainly good agreement with the measurements. The computations help to explain the reasons for the significant losses in total pressure and for the relatively low values of CD in this pre-swirl system.
Publisher
ASME International
Subject
Mechanical Engineering
Reference9 articles.
1. Popp, O., Zimmerman, H., and Kutz, J., 1998, “CFD Analysis of Cover-Plate Receiver Flow,” ASME J. Turbomach., 120, pp. 43–49. 2. Karabay, H., Chen, J. X., Pilbrow, R., Wilson, M., and Owen, J. M., 1999, “Flow in a “Cover-Plate” Pre-Swirl Rotor-Stator System,” ASME J. Turbomach., 121, pp. 160–166. 3. Karabay, H., Wilson, M., and Owen, J. M., 2001, “Predictions of Effect of Swirl on Flow and Heat Transfer in a Rotating Cavity,” Int. J. Heat Fluid Flow, 22(2), pp. 143–155. 4. Meierhofer, B., and Franklin, C. J., 1981, “An Investigation of a Pre-swirled Cooling Airflow to a Gas Turbine Disk by Measuring the Air Temperature in the Rotating Channels,” ASME Paper 81-GT-132. 5. Wilson, M., Pilbrow, R., and Owen, J. M., 1997, “Flow and Heat Transfer in a Pre-Swirl Rotor-Stator System,” ASME J. Turbomach., 119, pp. 364–373.
Cited by
44 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|