Transient Natural Convection Heat Transfer Correlations for Tube Bundles Immersed in a Thermal Storage

Author:

Su Yan1,Davidson Jane H.1

Affiliation:

1. Department of Mechanical Engineering, University of Minnesota, 111 Church Street S.E., Minneapolis, MN 55455

Abstract

A scale analysis of the transient discharge of a fully mixed thermal storage vessel with an immersed single-tube heat exchanger is extended to provide a generalized expression for the transient natural convection Nusselt number for heat exchangers comprising many tubes. The transient Nusselt number is expressed in terms of the Rayleigh number at the initiation of the discharge (or charge) process and easily measured geometric parameters. Nusselt numbers measured for a 240-tube heat exchanger immersed in a fully mixed 126L storage vessel are well correlated in the proposed form. The applicability of the approach to thermally stratified storage fluids is evaluated for both a single-tube and the 240-tube bundle. For heat exchangers of practical size for solar systems, for example the 240-tube bundle, buoyancy driven flow within the storage is sufficient to mix an initially stratified fluid. In this case, Nusselt numbers during the discharge process are predicted accurately by the proposed transient formulation. However, if the storage fluid remains stratified during discharge, as is the case for an initially stratified vessel with a single-tube heat exchanger, the transient formulation is not recommended.

Publisher

ASME International

Subject

Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment

Reference11 articles.

1. Natural Convection From a Horizontal Tube Heat Exchanger Immersed in a Tilted Enclosure;Liu;J. Sol. Energy Eng.

2. Natural Convection From a Tube Bundle in a Thin Inclined Enclosure;Liu;J. Sol. Energy Eng.

3. Thermal Characterization of Prototypical ICS Systems With Immersed Heat Exchangers;Liu;J. Sol. Energy Eng.

4. Farrington, R. B., and Bingham, C. E., 1986, “Testing and Analysis of Immersed Heat Exchangers,” SERI Report No. TR-253-2866, Solar Energy Research Institute (now National Renewable Energy Laboratory), Golden, CO.

5. Farrington, R. B. , 1986, “Test Results of Immersed Coil Heat Exchangers and Liquid Storage Tanks Used in the Packaged Systems Program,” SERI Report No. TR-254-2841, Solar Energy Research Institute (now National Renewable Energy Laboratory), Golden, CO.

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Enhancement of thermal energy storage using phase changing material;9TH NATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN MECHANICAL ENGINEERING [RDME 2021];2022

2. Comparison of circular- and cross-oriented phase-changing material spherical balls for charging and discharging cycles;International Journal of Ambient Energy;2021-11-22

3. Experimental study on heat discharging characteristic of single tank with different annular baffle conditions;International Journal of Energy Research;2020-08-12

4. A novel approach for modelling thermal energy storage with phase change materials and immersed coil heat exchangers;International Journal of Heat and Mass Transfer;2019-06

5. Heat Discharge of Molten Salt in Double Energy Storage Tank;Advances in Intelligent Systems and Computing;2019-03-17