Assessment of Probe-to-Specimen Distance Effect in Kidney Stone Treatment With Hydrodynamic Cavitation

Author:

Uzusen Dogan1,Demir Ebru1,Yavuz Perk Osman1,Oral Ozlem2,Ekici Sinan3,Unel Mustafa1,Gozuacik Devrim4,Kosar Ali5

Affiliation:

1. Mechatronics Engineering Program, Faculty of Engineering and Natural Sciences, Sabancı University, Orhanli, Istanbul 34956, Turkey e-mail:

2. Biological Sciences and Bioengineering Program, Faculty of Engineering and Natural Sciences, Sabanci University Nanotechnology Research and Application Center, Sabancı University, Orhanli, Tulza, Istanbul 34956, Turkey e-mail:

3. Department of Urology, Maltepe University Hospital, Maltepe University, Maltepe, Istanbul 34956, Turkey e-mail:

4. Molecular Biology, Genetics and Bioengineering Program, Faculty of Engineering and Natural Sciences, Sabancı University, Orhanli, Tuzla, Istanbul 34956, Turkey e-mail:

5. Mem. ASME Mechatronics Engineering Program, Faculty of Engineering and Natural Sciences, Sabancı University, Orhanli, Istanbul 34956, Turkey e-mail:

Abstract

The aim of this study is to focus on the effect of probe-to-specimen distance in kidney stone treatment with hydrodynamic bubbly cavitation. Cavitating bubbles were generated by running phosphate buffered saline (PBS) through stainless steel tubing of inner diameter of 1.56 mm at an inlet pressure of ∼10,000 kPa, which was connected to a 0.75 mm long probe with an inner diameter of 147 μm at the exit providing a sudden contraction and thus low local pressures. The bubbles were targeted on the surface of nine calcium oxalate kidney stones (submerged in a water pool at room temperature and atmospheric pressure) from three different distances, namely, 0.5 mm, 2.75 mm, and 7.75 mm. The experiments were repeated for three different time durations (5 min, 10 min, and 20 min). The experimental data show that amongst the three distances considered, the distance of 2.75 mm results in the highest erosion amount and highest erosion rate (up to 0.94 mg/min), which suggests that a closer distance does not necessarily lead to a higher erosion rate and that the probe-to-specimen distance is a factor of great importance, which needs to be optimized. In order to be able to explain the experimental results, a visualization study was also conducted with a high speed CMOS camera. A new correlation was developed to predict the erosion rates on kidney stones exposed to hydrodynamic cavitation as a function of material properties, time, and distance.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference38 articles.

1. Water Disinfection by Acoustic and Hydrodynamic Cavitation;Biochem. Eng. J.,2001

2. Hydrodynamic Cavitation and Boiling in Refrigerant (R-123) Flow Inside Microchannels;Int. J. Heat Mass Transfer,2007

3. Preparation of Biodiesel With the Help of Ultrasonic and Hydrodynamic Cavitation;Ultrasonics,2006

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3