Affiliation:
1. Hitachi, Ltd., Hitachi, Ibaraki, Japan
Abstract
In this paper, the development leading to a 17-stage axial flow compressor (pressure ratio 14.7) for the 25 MW class heavy duty gas turbine H-25 is described. In the course of developing the H-25’s compressor, extensive measurements were carried out on models. Experimental results are compared with predicted values. Aerodynamic experiments covered the measurements of unsteady flows such as rotating stall and surge as well as the steady-state performance of the compressor.
Based on the results of these tests, the aerodynamic and mechanical design parameters of the full scale H-25 compressor were finalized on the basis of two model compressors.
Detailed measurements of the first unit of the H-25 gas turbine were carried out. Test results on the compressor are presented and show the achievement of the expected design targets.
Publisher
American Society of Mechanical Engineers
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献