Abstract

Detailed blood velocity map in the vascular system can be obtained by applying the optical flow method (OFM) in processing fluoroscopic digital subtracted catheter angiographic images; however, there are still challenges with the accuracy of this method. In the present study, a divergence compensatory optical flow method (DC-OFM), in which a nonzero divergence of velocity is assumed due to the finite resolution of the image, was explored and applied to the digital subtraction angiography (DSA) images of blood flow. The objective of this study is to examine the applicability and evaluate the accuracy of DC-OFM in assessing the blood flow velocity in vessels. First, an Oseen vortex flow was simulated on the standard particle image to generate an image pair. Then, the DC-OFM was applied on the particle image pair to recover the velocity field for validation. Second, DSA images of intracranial arteries were used to examine the accuracy of the current method. For each set of images, the first image is the in vivo DSA image, and the second image is generated by superimposing a given flow field. The recovered velocity map by DC-OFM agrees well with the exact velocity for both the particle images and the angiographic images. In comparison with the traditional OFM, the present method can provide more accurate velocity estimation. The accuracy of the velocity estimation can also be improved by implementing preprocess techniques including image intensification, Gaussian filtering, and “image-shift.”

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3