Prosthetic Ankle-Foot System That Adapts to Sloped Surfaces

Author:

Nickel Eric A.1,Hansen Andrew H.1,Gard Steven A.2

Affiliation:

1. Minneapolis VA Health Care System, One Veterans Dr. (Research 151), Minneapolis, MN 55417

2. Northwestern University Prosthetics-Orthotics Center, 680 N. Lakeshore Dr. Suite 1100, Chicago, IL 60611

Abstract

The anatomical ankle is capable of providing adaptation to sloped surfaces, a function that is not available in most traditional lower limb prostheses. Commercial prostheses that are claimed to adapt to slopes are limited by high cost, delay in response, reduced stability, and loss of energy through damping. The purpose of the present work was to develop a prototypical prosthetic ankle unit that adapts to sloped surfaces and is sufficiently durable for short-term take-home trials. The prototype switches between low and high rotational impedances by means of a wrap spring clutch mechanism. The clutch is held in a disengaged position when unloaded and deflection of a compressible pylon under axial load rotates a control collar and engages the clutch. The prototype was subjected to 100,000 cycles of mechanical endurance testing based on ISO 10328 standards to determine the suitability for two-week take-home testing. Three persons with unilateral transtibial amputations were recruited to test the prototype in the laboratory, providing subjective feedback through a survey and participating in a motion analysis study to confirm the performance of the slope adaptation function. Translation of the ankle moment-angle curves for all subjects along the ankle angle axis demonstrated a change of the ankle alignment when subjects walked with the adaptable ankle on surfaces of different slopes. The ankle moment-angle curves had a lower slope than the subjects’ usual prostheses, and some subjects had distinct flat regions in the moment-angle curves when using the adaptable ankle. The arbors of the clutch demonstrated significant wear when tested to 100,000 cycles based on ISO 10328 standards, yet the adaptable ankle continued to hold testing loads. The alignment change observed for sloped surfaces suggests the prototype was providing slope adaptation. The flat regions on the ankle moment-angle curves suggest the clutch may have been slipping. Refinement of the clutch engagement mechanism and continued development to reduce the weight and size of the prototype is needed prior to take-home testing.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference17 articles.

1. Roll-Over Characteristics of Human Walking on Inclined Surfaces;Hansen;Hum. Mov. Sci.

2. Postural Adaptations to Walking on Inclined Surfaces: I. Normal Strategies;Leroux;Gait and Posture

3. Ruhe, B. , 2007, “Investigations of Standing Balance Efficiency on Sloped Surfaces in Persons With Transfemoral Amputation,” Ph.D. thesis, Northwestern University, Evanston, IL.

4. Runners Adjust Leg Stiffness for Their First Step on a New Running Surface;Ferris;J. Biomech.

5. Locomotor Adaptations for Changes in the Slope of the Walking Surface;Prentice;Gait and Posture

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3