Design and Performance Testing of a Novel In Vivo Laparoscope Lens Cleaning Device

Author:

Idelson Christopher1,Uecker John2,Garcia James A.3,Kohli Sunjna4,Handing Greta4,Sriramprasad Vishrudh3,Yong Kirstie3,Rylander Christopher5

Affiliation:

1. ClearCam Inc., Austin, TX 78744; Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712

2. ClearCam Inc., Austin, TX 78744; Department of Surgery and Perioperative Care, Dell Medical School, The University of Texas at Austin, Austin, TX 78712

3. Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712

4. Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712

5. ClearCam Inc., Austin, TX 78744; Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712; Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712

Abstract

Abstract A common tool for diagnosis and treatment of gastrointestinal, gynecologic, and other anatomical pathologies is a form of minimally invasive surgery known as laparoscopy. Roughly 4 × 106 laparoscopic surgeries are performed in the U.S. every year, with an estimated 15 × 106 globally. During surgeries, lens clarity often becomes impaired via (1) condensation or (2) smearing of bodily fluids and tissues. The current gold standard solution requires scope removal from the body for cleaning, offering opportunity for decreased surgical safety and efficiency, while simultaneously generating mounting frustration for the operating room team. A novel lens cleaning device was designed and developed to clean a laparoscope lens in vivo during surgery. Benchtop experiments in a warm body simulated environment allowed quantification of lens cleaning efficacy for several lens contaminants. Image analysis techniques detected the differences between original (clean), postdebris, and postcleaning images. Mechanical testing was also executed to determine safety levels regarding potential misuse scenarios. Compared to gold standard device technologies, the novel lens cleaning device prototype showed strong performance and ability to clear a laparoscope lens of debris while mitigating the need for scope removal from the simulated surgical cavity. Mechanical testing results also suggest the design also holds inherently strong safety performance. Both objective metrics and subjective observation suggests the novel design holds promise to improve safety and efficiency during laparoscopic surgery.

Funder

National Science Foundation

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference56 articles.

1. 3.5 Million Laparoscopic Procedures Performed in the U.S. Across 12 Procedure Types According to IData Procedure Tracker;iData Res,2017

2. Laparosopic Market Dynamics;LAPDOME,2017

3. The Trend Towards Minimally Invasive Surgery (MIS) for Endometrial Cancer: An ACS-NSQIP Evaluation of Surgical Outcomes;Gynecol. Oncol.,2015

4. Distribution and Volume of Extrauterine Disease in Uterine Serous Carcinoma: Is Minimally Invasive Surgery a Suitable Approach?;Int. J. Gynecol. Cancer,2015

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3