Bayesian Calibration for Power Splitting in Single Shaft Combined Cycle Plant Diagnostics

Author:

Jiang Xiaomo1,Mendoza Eduardo1,Lin TsungPo1

Affiliation:

1. General Electric Company, Atlanta, GA

Abstract

Condition monitoring and diagnostics of a combined cycle gas turbine power plant has become an important tool to improve its availability, reliability, and performance. However, there are two major challenges in the diagnostics of performance degradation and anomaly in a single shaft combined cycle power plant. First, since the gas turbine and steam turbine in such a plant share a common generator, each turbine’s contribution to the total plant power output is not directly measured, but must be accurately estimated to identify the possible causes of plant level degradation. Second, multivariate operational data instrumented from a power plant need to be used in the plant model calibration, power splitting and degradation diagnostics. Sensor data always contains some degree of uncertainty. This adds to the difficulty of both estimation of gas turbine to steam turbine power split and degradation diagnostics. This paper presents an integrated probabilistic methodology for accurate power splitting and the degradation diagnostics of a single shaft combined cycle plant, accounting for uncertainties in the measured data. The method integrates the Bayesian inference approach, thermodynamic physics modeling, and sensed operational data seamlessly. The physics-based thermodynamic heat balance model is first established to model the power plant components and their thermodynamic relationships. The model is calibrated to model the plant performance at the design conditions of its main components. The calibrated model is then employed to simulate the plant performance at various operating conditions. A Bayesian inference method is next developed to determine the power split between the gas turbine and the steam turbine by comparing the measured and expected power outputs at different operation conditions, considering uncertainties in multiple measured variables. The calibrated model and calculated power split are further applied to pinpoint the possible causes at individual components resulting in the plant level degradation. The proposed methodology is demonstrated using operational data from a real-world single shaft combined cycle power plant with a known degradation issue. This study provides an effective probabilistic methodology to accurately split the power for degradation diagnostics of a single shaft combined cycle plant, addressing the uncertainties in multiple measured variables.

Publisher

American Society of Mechanical Engineers

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Estimation and monitoring of unmeasured gas turbine variables;Transactions of the Canadian Society for Mechanical Engineering;2019-03-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3