An Analytical Approach to Determine the in Situ Forces in the Glenohumeral Ligaments
Author:
Debski R. E.1, Wong E. K.1, Woo S. L-Y.1, Fu F. H.1, Warner J. J. P.1
Affiliation:
1. Musculoskeletal Research Center, Department of Orthopædic Surgery, University of Pittsburgh, Pittsburgh, PA 15213
Abstract
The purpose of this study was to use an analytical approach to determine the forces in the glenohumeral ligaments during joint motion. Predictions from the analytical approach were validated by comparing them to experimental data. Using a geometric model, the lengths of the four glenohumeral ligaments were determined during anterior-posterior loading simulations and forward flexion-extension. The corresponding force in each structure was subsequently calculated based on length data via load-elongation curves obtained experimentally. During the anterior loading simulation at 0 deg of abduction, the superior glenohumeral ligament carried up to 71 N at the maximally translated position. At 90 deg of abduction, the anterior band of the inferior glenohumeral ligament had the highest force of 45 N during anterior loading. These results correlated well with those found in previous experimental studies. We believe that this validated analytical approach can be used to predict the forces in the glenohumeral ligaments during more complex joint motion as well as assist surgeons during shoulder repair procedures.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference24 articles.
1. An
K. N.
, BrowneA. O., KorinekS. L., TanakaS., and MorreyB. F., 1991, “Three-dimensional kinematics of glenohumeral elevation,” J. Orthop. Res., Vol. 9, pp. 143–149. 2. Bigliani
L. U.
, PollockR. G., SoslowskyL. J., FlatowE. L., PawlukR. J., and MowV. C., 1992, “Tensile properties of the inferior glenohumeral ligament,” J. Orthop. Res., Vol. 10, pp. 187–197. 3. Boardman
N. D.
, DebskiR. E., WarnerJ. J. P., TaskiranE., MaddoxL., ImhoffA. B., FuF. H., and WooS. L.-Y., 1996, “Tensile properties of the superior glenohumeral and coracohumeral ligaments,” J. Shoulder Elbow Surg., Vol. 5, pp. 249–254. 4. Debski
R. E.
, McMahonP. J., ThompsonW. O., WooS. L.-Y., WarnerJ. J. P., and FuF. H., 1995, “A new dynamic testing apparatus to study glenohumeral motion,” J. Biomech., Vol. 28, pp. 869–874. 5. Debski
R. E.
, WongE. K., SakaneM., WarnerJ. J. P., FuF. H., and WooS. L-Y., 1997, “Application of robotic/UFS technology to study the in-situ load distribution in the glenohumeral joint capsule during A-P loading,” Advances in Bioengineering, Vol. 35, pp. 333–334.
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|