Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response

Author:

Pena Mirle12,Neu Dylan T.3,Feng H. Amy3,Hammond Duane R.3,Mead Kenneth R.3,Banerjee Rupak K.4

Affiliation:

1. Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention , Cincinnati, OH 45226 ; , Cincinnati, OH 45221

2. Department of Biomedical Engineering, University of Cincinnati , Cincinnati, OH 45226 ; , Cincinnati, OH 45221

3. Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention , Cincinnati, OH 45226

4. Department of Mechanical and Biomedical Engineering, University of Cincinnati, 593 Rhodes Hall , 2600 Clifton Ave, Cincinnati, OH 45221

Abstract

Abstract Emergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, “Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study,” Lancet Pub. Health, 5(9), pp. e475–e483; Brown et al., 2021, “Risk for Acquiring Coronavirus Disease Illness Among Emergency Medical Service Personnel Exposed to Aerosol-Generating Procedures,” Emer. Infect. Disease J., 27(9), p. 2340). The use of protective equipment may reduce, but does not eliminate their risk of becoming infected as a result of these exposures. Prehospital environments have a high risk of disease transmission exposing EMS providers to bioaerosols and droplets from infectious patients. Field intubation procedures may be performed causing the generation of bioaerosols, thereby increasing the exposure of EMS workers to pathogens. Additionally, ambulances have a reduced volume compared to a hospital treatment space, often without an air filtration system, and no control mechanism to reduce exposure. This study evaluated a containment plus filtration intervention for reducing aerosol concentrations in the patient module of an ambulance. Aerosol concentration measurements were taken in an unoccupied research ambulance at National Institute for Occupational Safety and Health (NIOSH) Cincinnati using a tracer aerosol and optical particle counters (OPCs). The evaluated filtration intervention was a containment pod with a high efficiency particulate air (HEPA)-filtered extraction system that was developed and tested based on its ability to contain, capture, and remove aerosols during the intubation procedure. Three conditions were tested (1) baseline (without intervention), (2) containment pod with HEPA-1, and (3) containment pod with HEPA-2. The containment pod with HEPA-filtered extraction intervention provided containment of 95% of the total generated particle concentration during aerosol generation relative to the baseline condition, followed by rapid air cleaning within the containment pod. This intervention can help reduce aerosol concentrations within ambulance patient modules while performing aerosol-generating procedures.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference42 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3