Theoretical Accuracy of Model-Based Shape Matching for Measuring Natural Knee Kinematics with Single-Plane Fluoroscopy

Author:

Fregly Benjamin J.12,Rahman Haseeb A.3,Banks Scott A.4

Affiliation:

1. (352) 392-8157 (352) 392-7303

2. Department of Mechanical and Aerospace Engineering, Department of Biomedical Engineering, Department of Othopaedics and Rehabilitation, University of Florida, Gainesville, FL 32611

3. Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611

4. Department of Mechanical and Aerospace Engineering, Department of Orthopaedics and Rehabilitation, University of Florida, Gainesville, FL 32611 and The Biomotion Foundation, West Palm Beach, FL 33480

Abstract

Quantification of knee motion under dynamic, in vivo loaded conditions is necessary to understand how knee kinematics influence joint injury, disease, and rehabilitation. Though recent studies have measured three-dimensional knee kinematics by matching geometric bone models to single-plane fluoroscopic images, factors limiting the accuracy of this approach have not been thoroughly investigated. This study used a three-step computational approach to evaluate theoretical accuracy limitations due to the shape matching process alone. First, cortical bone models of the femur, tibia/fibula, and patella were created from CT data. Next, synthetic (i.e., computer generated) fluoroscopic images were created by ray tracing the bone models in known poses. Finally, an automated matching algorithm utilizing edge detection methods was developed to align flat-shaded bone models to the synthetic images. Accuracy of the recovered pose parameters was assessed in terms of measurement bias and precision. Under these ideal conditions where other sources of error were eliminated, tibiofemoral poses were within 2mm for sagittal plane translations and 1.5deg for all rotations while patellofemoral poses were within 2mm and 3deg. However, statistically significant bias was found in most relative pose parameters. Bias disappeared and precision improved by a factor of two when the synthetic images were regenerated using flat shading (i.e., sharp bone edges) instead of ray tracing (i.e., attenuated bone edges). Analysis of absolute pose parameter errors revealed that the automated matching algorithm systematically pushed the flat-shaded bone models too far into the image plane to match the attenuated edges of the synthetic ray-traced images. These results suggest that biased edge detection is the primary factor limiting the theoretical accuracy of this single-plane shape matching procedure.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference24 articles.

1. Centers for Disease Control and Prevention, 2003, “Targeting Arthritis: The Nation’s Leading Cause of Disability,” National Center for Chronic Disease Prevention and Health Promotion, Atlanta, Georgia, http://www.cdc.gov/nccdphp/aag/pdf/aag̱arthritis2003.pdf.

2. In Vivo Knee Joint Loading and Kinematics Before and After ACL Transection in an Animal Model;Hasler;J. Biomech.

3. Tashman, S., Anderst, W., and Kolowich, P., 1999, “Severity of OA Related to Magnitude of Dynamic Instability in ACL-Deficient Dogs,” Transactions of the 46th Annual Meeting of the Orthopaedic Research Society, Orlando, FL, pp. 257.

4. Three-Dimensional Analysis of Human Walking: Experimental Methods and Associated Artifacts;Cappozzo;Hum. Mov. Sci.

5. Surface Marker Cluster Design Criteria for 3-D Bone Movement Reconstruction;Cappozzo;IEEE Trans. Biomed. Eng.