Affiliation:
1. Northeastern University, Boston, Massachusetts, United States
Abstract
Abstract
Polystyrene particles simulating bacteria flow down a micro-channel in the presence of potassium chloride solution. Depending on the ionic concentration or flow rates, portion of the particles are trapped on the glass substrate due to intrinsic surface forces. A novel quartz crystal microbalance (QCM) is built into the microfluidic device to track the real-time particle deposition by shift of the resonance frequency. The new technique is promising to quantify water filtration.
Publisher
American Society of Mechanical Engineers
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献