A Model of Strain-Dependent Glomerular Basement Membrane Maintenance and Its Potential Ramifications in Health and Disease

Author:

Barocas Victor H.1,Dorfman Kevin D.2,Segal Yoav3

Affiliation:

1. Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455

2. Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, MN 55455

3. Division of Renal Diseases and Hypertension, Department of Medicine, University of Minnesota, Minneapolis, MN 55455; Minneapolis VA Health Care System, Minneapolis, MN 55417

Abstract

A model is developed and analyzed for type IV collagen turnover in the kidney glomerular basement membrane (GBM), which is the primary structural element in the glomerular capillary wall. The model incorporates strain dependence in both deposition and removal of the GBM, leading to an equilibrium tissue strain at which deposition and removal are balanced. The GBM thickening decreases tissue strain per unit of transcapillary pressure drop according to the law of Laplace, but increases the transcapillary pressure drop required to maintain glomerular filtration. The model results are in agreement with the observed GBM alterations in Alport syndrome and thin basement membrane disease, and the model-predicted linear relation between the inverse capillary radius and inverse capillary thickness at equilibrium is consistent with published data on different mammals. In addition, the model predicts a minimum achievable strain in the GBM based on the geometry, properties, and mechanical environment; that is, an infinitely thick GBM would still experience a finite strain. Although the model assumptions would be invalid for an extremely thick GBM, the minimum achievable strain could be significant in diseases, such as Alport syndrome, characterized by focal GBM thickening. Finally, an examination of reasonable values for the model parameters suggests that the oncotic pressure drop—the osmotic pressure difference between the plasma and the filtrate due to large molecules—plays an important role in setting the GBM strain and, thus, leakage of protein into the urine may be protective against some GBM damage.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference78 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3