Affiliation:
1. Johannes Kepler University Linz, Linz, Austria
2. Linz Center of Mechatronics, Linz, Austria
Abstract
In a series of experiments the peak current during switch on of a fast switching valve, which was found to be out of tolerances with respect to some armature dimensions, was varied to realize different switch on times. Despite the fact that the holding current was identical for all cases and the time between switch on and off was very long, the valve’s switch off time showed an unexpected dependency on the switch on peak current value. This paper presents an explanation of this phenomenon by coarse mathematical models, demonstrating that the manufacturing error in combination with friction, skewness, and fluid stiction are responsible for this behavior.
Publisher
American Society of Mechanical Engineers
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献