Affiliation:
1. Rolls-Royce Limited, Derby, England
2. Whittle Laboratory, University of Cambridge, England
Abstract
Aerodynamic loss measurements are presented for a state-of-the-art film cooled transonic gas turbine rotor blade tested in a two-dimensional cascade. A mixture of carbon dioxide and air, which correctly simulated engine coolant-to-mainstream density ratio and blowing rate, was ejected from each of five individual cooling hole rows in the aerofoil suction surface. The temperature of the coolant was equal to the cascade inlet stagnation temperature. The dependence of blade row efficiency and turning on outlet Mach number, blowing rate, and coolant-to-mainstream density ratio was investigated. Measured surface static pressure distributions were compared with time-marching predictions for both the datum aerofoil and film cooled blades. Detailed suction surface boundary layer measurements both upstream and downstream of a cooling film were compared with available differential calculation procedures. Unexpectedly, films downstream of the throat, even at blowing rates near unity, did not generate significantly higher losses compared to prethroat suction surface films on this aerofoil.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
28 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献