Affiliation:
1. Department of Fuel and Energy, University of Leeds, Leeds LS2 9JT, United Kingdom
Abstract
Factors influencing the design of full coverage drilled plate wall cooling systems for gas turbine combustors are studied. It is shown that the large number of small diameter holes required result in a low Reynolds number operating regime. The physical features giving rise to the hole pressure loss are examined, and it is shown that under hot conditions heat transfer within the hole can appreciably alter the hole mass flow for a fixed pressure loss. It is shown that this effect may be used to estimate the hole outlet temperature and the results show that the heat transfer within the combustor wall may be very significant. The rise in coolant temperature within the wall appreciably alters the blowing rate and hence influences the hot gas side convective heat transfer to the plate. The influence of an impingement plate on hole discharge coefficients is also investigated and shown to be small.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献