Affiliation:
1. Lehrstuhl und Institut fu¨r Thermische Stro¨mungsmaschinen, Universita¨t Karlsruhe, D-7500 Karlsruhe, 1, West Germany
Abstract
The mixing of coolant air jets with the hot gas exiting the primary zone is of major importance to the combustor exit temperature profile. Geometry and momentum flux ratios are the dominant parameters. A theoretical and experimental study of single as well as opposite-wall jet injection into a hot crossflow reveals the applicability and limitations of existing correlations. Modified correlations are presented for opposite-wall injection with jets of different momentum flux ratios. The advantages in applying field methods for describing the flow are discussed.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
26 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献