The Effect of Stem Circumferential Grooves on the Stability at the Implant-Cement Interface

Author:

Hosein Yara K.1,King Graham J. W.2,Dunning Cynthia E.3

Affiliation:

1. Biomedical Engineering Graduate Program, Western University, London, ON N6A 5B9, Canada

2. Department of Surgery, Western University, London, ON N6A 5B9, Canada

3. Biomedical Engineering Graduate Program, Department of Surgery, and Department of Materials & Mechanical Engineering, Western University, London, ON N6A 5B9, Canada e-mail:

Abstract

The application of stem surface treatments and finishes are common methods for improving stem-cement interface stability in joint replacement systems; however, success of these surfaces has been variable. As opposed to applying a treatment or finish, altering stem design through changing the surface topography of the base stem material may offer some advantages. This study compared the effect of stem circumferential grooving on the torsional and axial stability of cemented stems. Fifteen metal stems were machined from cobalt chrome to have smooth (n = 5) or circumferential-grooved surfaces, where groove depth and spacing was either 0.6 mm (n = 5) or 1.1 mm (n = 5). Stems were potted in aluminum tubes using bone cement, left 24 h to cure, and placed in a materials testing machine for testing using a cyclic staircase loading protocol at 1.5 Hz. All stems were tested independently in compression and torsion on separate testing days, using the same stems repotted with new cement. Motion of the stem was tracked, and failure was defined either as rapid increase in stem motion, or completion of the loading protocol. Statistical analysis was used to compare interface strength and stem motion prior to failure. Grooved stems demonstrated increased interface strength (p < 0.001) and reduced motion (p < 0.01) compared to smooth stems under compression. In torsion, no significant difference was found in strength among the grooved and smooth stems (p = 0.10); however, grooved 1.1 mm demonstrated greatest interface motion prior to catastrophic failure (p < 0.01). Overall, circumferential-grooved stems offered improved stability under compression, and comparable stability in torsion, relative to the smooth stems.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference31 articles.

1. Eleven Year Report—January 1999 to December 2009;New Zealand Orthopaedic Association,2010

2. National Joint Registry, Hip and Knee Arthroplasty Annual Report 2010;Australian Orthopaedic Association,2010

3. Early Loosening of the Femoral Component at the Cement-Prosthesis Interface After Total Hip Replacement;J. Bone Joint Surg., Am. Vol.,1995

4. Complications of Total Elbow Arthroplasty;J. Am. Acad. Orthop. Surg.,2011

5. Elbow Joint Force Predictions for Some Strenuous Isometric Actions;J. Biomech.,1980

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3