Positive Feedback in Powered Exoskeletons: Improved Metabolic Efficiency at the Cost of Reduced Stability?

Author:

Norris James A.1,Marsh Anthony P.2,Granata Kevin P.3,Ross Shane D.3

Affiliation:

1. School of Biomedical Engineering & Sciences, Winston-Salem, NC

2. Wake Forest University, Winston-Salem, NC

3. Virginia Polytechnic Institute and State University, Blacksburg, VA

Abstract

A broad objective of many lower extremity exoskeletons is to allow the wearer to expend less of their own energy for locomotion. Existing exoskeleton control algorithms are based on positive feedback. Forces are generated to augment movement initiated by the wearer. Positive feedback, however, can have destabilizing effects in dynamic systems. In fact, stability in these lower extremity exoskeletons is achieved by relying on the wearer’s neuromuscular system. Relying on the wearer to maintain stability may increase metabolic demand, which is counter productive to increasing efficiency. Thus, the goal of this study was to measure how a simple form of positive feedback that augments ankle push-off power affects both metabolic efficiency and dynamic walking stability. We developed a pair of powered ankle-foot orthoses (PAFOs) similar in design to Ferris, et al. (J. Appl. Biomech. 21, 189–197, 2005). Nine young healthy adults (23.3±1.6 years) walked on a treadmill in the PAFOs under two conditions: (1) with and (2) without push-off power assistance. Metabolic energy expenditure was calculated using indirect calorimetry. Walking stability was quantified using techniques for studying stability of dynamic system trajectories. The maximum Lyapunov exponent for assessing local dynamic stability, and the maximum Floquet multiplier magnitude for assessing orbital stability were calculated from foot and shank kinematics for each condition. Greater Lyapunov exponents and Floquet multipliers indicate decreased stability. Walking with mechanically generated push-off power increased metabolic efficiency (2.58±0.39 to 2.97±0.38, p<0.01), did not affect local dynamic stability (0.14±0.02 to 0.14±0.02, p = 0.77), but decreased orbital dynamic stability (0.43±0.03 to 0.48±0.06, p = 0.05). This study provides evidence that positive feedback can negatively affect stability. Further investigations into understanding stability of movement will be necessary for the design of controllers for powered lower extremity exoskeletons.

Publisher

ASMEDC

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3