Are Geometrical and Structural Variations Along the Length of the Aorta Governed by a Principle of “Optimal Mechanical Operation”?

Author:

Rachev Alexander1,Greenwald Stephen2,Shazly Tarek3

Affiliation:

1. Biomedical Engineering Program, College of Engineering and Computing, University of South Carolina, Columbia, SC 29208

2. Pathology Group, Blizard Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London E1 2ES, UK

3. Biomedical Engineering Program, College of Engineering and Computing, University of South Carolina, Columbia, SC 29208; Mechanical Engineering Department, College of Engineering and Computing, University of South Carolina, Columbia, SC 29208

Abstract

It is well-documented that the geometrical dimensions, the longitudinal stretch ratio in situ, certain structural mechanical descriptors such as compliance and pressure-diameter moduli, as well as the mass fractions of structural constituents, vary along the length of the descending aorta. The origins of and possible interrelations among these observed variations remain open questions. The central premise of this study is that having considered the variation of the deformed inner diameter, axial stretch ratio, and area compliance along the aorta to be governed by the systemic requirements for flow distribution and reduction of cardiac preload, the zero-stress state geometry and mass fractions of the basic structural constituents of aortic tissue meet a principle of optimal mechanical operation. The principle manifests as a uniform distribution of the circumferential stress in the aortic wall that ensures effective bearing of the physiological load and a favorable mechanical environment for mechanosensitive vascular smooth muscle cells. A mathematical model is proposed and inverse boundary value problems are solved for the equations that follow from finite elasticity, structure-based constitutive modeling within constrained mixture theory, and stress-induced control of aortic homeostasis, mediated by the synthetic activity of vascular smooth muscle cells. Published experimental data are used to illustrate the predictive power of the proposed model. The results obtained are in agreement with published experimental data and support the proposed principle of optimal mechanical operation for the descending aorta.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference34 articles.

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3