Simulating Dynamic Activities Using a Five-Axis Knee Simulator
Author:
Maletsky Lorin P.1, Hillberry Ben M.2
Affiliation:
1. Department of Mechanical Engineering, The University of Kansas, 1530 W. 15th St., 3138 Learned Hall, Lawrence, KS 66045-2234 2. School of Mechanical Engineering, Purdue University, Mechanical Engineering Building, #1288, West Lafayette, IN 47907-1288
Abstract
This work describes the design and capabilities of the Purdue Knee Simulator: Mark II and a sagittal-plane model of the machine. This five-axis simulator was designed and constructed to simulate dynamic loading activities on either cadaveric knee specimens or total knee prostheses mounted on fixtures. The purpose of the machine was to provide a consistent, realistic loading of the knee joint, allowing the kinematics and specific loading of the structures of the knee to be determined based on condition, articular geometry, and simulated activity. The sagittal-plane model of the knee simulator was developed both to predict the loading at the knee from arbitrary inputs and to generate the necessary inputs required to duplicate specified joint loading. Measured tibio-femoral compressive force and quadriceps tension were shown to be in good agreement with the predicted loads from the model. A controlled moment about the ankle-flexion axis was also shown to change the loading on the quadriceps.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference32 articles.
1. Ahmed, A. M., Burke, D. L., and Yu, A., 1983, “In vitro Measurement of Static Pressure Distribution in Synovial Joints—Part II: Retropateller Surface,” ASME J. Biomech. Eng., 105, pp. 226–236. 2. van Kampen, A., and Huiskes, R., 1990, “The Three-Dimensional Tracking Pattern of the Human Patella,” J. Orthop. Res., 8, pp. 372–382. 3. Biden, E., and O’Connor, J., 1990, “Experimental Methods Used to Evaluate Knee Ligament Function,” in Knee Ligaments: Structure, Function, Injury, and Repair, Raven Press, New York, NY, Chap. 8, pp. 135–151. 4. Whiteside, L. A., Kasselt, M. R., and Haynes, D. W., 1987, “Varus-Valgus and Rotational Stability in Rotationally Unconstrained Total Knee Arthroplasty,” Clin. Orthop. Relat. Res., 219, pp. 147–157. 5. Bach, J. M., and Hull, M. L., 1994, “Description and Evaluation of a New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee Joint,” ASME Bioeng. Div. Publ. Bed., 28, pp. 283–284.
Cited by
72 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|